Part Number |
Description |
A415FNFI1 |
Elcometer 415 Paint and Powder Coating Thickness Gauge |
A415FNFI1AUTO |
Elcometer 415 Automotive Gauge (complete with F & N calibration plates) |
Range |
0 to 1000µm (0 to 40mils) |
Resolution |
1µm (0.1mil) |
Accuracy |
±3% or ±3µm (±0.12mil) |
Measurement Speed |
Greater than 60 readings per minute |
Operating Temperature (ambient) |
0°C to 50°C (32°F to 120°F) |
Maximum Operating Temperature (probe) |
80°C (176°F) |
Storage Temperature |
-10°C to 55°C (14°F to 130ºF) |
Case |
High impact ABS plastic |
Batteries |
2 x LR03 (AAA) alkaline dry batteries or rechargeable equivalents |
Weight |
130g (4.1oz) |
Dimensions |
110 x 75 x 35mm (4.3 x 3 x 1.38”) |
Certificate available |
Certificate of Test - for variable calibration equipment and supplied with readings. A Certificate of Inspection states the instrument is tested in accordance with our procedures. |
Packing List |
Elcometer 415 gauge, 4 x calibration foils, soft carry case, 2 x LR03 batteries & operating instructions. The Elcometer 415 AUTO has 2 calibration zero plates |
Can be used in accordance with:
AS2331.1.4, AS/NZS 1580.108.1, ASTM B 499, ASTM D 1186, ASTM D 1400, ASTM D 7091, ASTM E 376,
BS 3900-C5-6A, BS 3900-C5-6B, BS 5411-11, BS 5411-3, BS 5599, DIN 50981, DIN 50984, ECCA T1, EN 13523-1,
ISO 2360, ISO 2808-12, ISO 2808-6A, ISO 2808-6B, ISO 2808-7C, ISO 2808-7D, JIS K 5600-1-7, NF T30-124
Standards in grey have been superseded but are still recognised in some industries.