Calibration Standards
Calibration standards are available as a set or individually, allowing users to select the most appropriate thickness for their application. Elcometer calibration standards are manufactured from 4340 steel to a tolerance of ± 0.1% of the nominal thickness and are supplied complete with calibration certificates.
|
Part Number
|
Description
|
T920CALSTD-SET1
|
Calibration standard set; Nominal Thickness 2-30mm (0.08-1.18”)1
Comprising of; 2, 5, 10, 15, 20, 25 & 30mm (0.08, 0.20, 0.39, 0.59, 0.79, 0.98 & 1.18”),
complete with holder & calibration certificate.
|
T920CALSTD-SET2
|
Calibration standard set; Nominal Thickness 40-100mm (1.57-3.94”)1
Comprising of; 40, 50, 60, 70, 80, 90 & 100mm (1.57, 1.97, 2.36, 2.76, 3.15, 3.54 & 3.94”),
complete with holder & calibration certificate.
|
T920CALSTD-HLD
|
Calibration Holder; for thicknesses up to 100mm (3.94")
|
T920CALSTD-2
|
Individual Calibration Standard, Nominal Thickness 2mm (0.078")1
|
T920CALSTD-5
|
Individual Calibration Standard, Nominal Thickness 5mm (0.196")1
|
T920CALSTD-10
|
Individual Calibration Standard, Nominal Thickness 10mm (0.393")1
|
T920CALSTD-15
|
Individual Calibration Standard, Nominal Thickness 15mm (0.590")1
|
T920CALSTD-20
|
Individual Calibration Standard, Nominal Thickness 20mm (0.787")1
|
T920CALSTD-25
|
Individual Calibration Standard, Nominal Thickness 25mm (0.984")1
|
T920CALSTD-30
|
Individual Calibration Standard, Nominal Thickness 30mm (1.181")1
|
T920CALSTD-40
|
Individual Calibration Standard, Nominal Thickness 40mm (1.574")1
|
T920CALSTD-50
|
Individual Calibration Standard, Nominal Thickness 50mm (1.966")1
|
T920CALSTD-60
|
Individual Calibration Standard, Nominal Thickness 60mm (2.362")1
|
T920CALSTD-70
|
Individual Calibration Standard, Nominal Thickness 70mm (2.755")1
|
T920CALSTD-80
|
Individual Calibration Standard, Nominal Thickness 80mm (3.149")1
|
T920CALSTD-90
|
Individual Calibration Standard, Nominal Thickness 90mm (3.543")1
|
T920CALSTD-100
|
Individual Calibration Standard, Nominal Thickness 100mm (3.937")1
|
|
|

Ultrasonic Couplant
Elcometer supplies a viscous gel to work on both horizontal and vertical surfaces. The temperature range for regular couplant is -15 to 104°C (5 to 220°F). The Elcometer high temperature gel has a range of up to 398°C (750°F) for use with high temperature transducers.
|
Part Number
|
Description
|
T92015701
|
Ultrasonic Couplant; 120ml (4fl oz)
|
T92015701-5
|
Ultrasonic Couplant; 120ml (4fl oz), Pack of 5 Bottles
|
T92024034-7
|
Ultrasonic Couplant; 300ml (10fl oz)
|
T92024034-8
|
Ultrasonic Couplant; 500ml (17fl oz)
|
T92024034-3
|
Ultrasonic Couplant; 3.8 litres (1 US Gallon)
|
T92024034-9
|
High Temperature Couplant; 60ml (2fl oz)
For use with high temperature transducers up to 398°C (750°F)
|
T92024034-10
|
High Temperature Couplant; 60ml (2fl oz), Pack of 2
|
|
|

Transducer Adaptor
This adaptor allows dual element, ‘non-intelligent’ and other transducers with Lemo Connectors from Elcometer and other manufacturers to be used with the Elcometer 204.
|
Part Number
|
Description
|
T92024911
|
Dual Element Transducer Adaptor
|